KR600 Has obtained the authentication:TUV、ISO9001、ROHSS、UL:E312438 Download |
|
|
|
|
|
Application scope: Switchboard, ADSL, small electrical appliances |
|
|
| KR600 Electrical specification |
Products model |
IH |
IT |
IMax |
VMax |
Ttrip |
PDtyp |
RMin |
RMax |
R1Max |
fig |
(A) |
(A) |
(A) |
(V) |
(A) |
(S) |
(W) |
(Ω) |
(Ω) |
(Ω) |
KR600-150 |
0.15 |
0.30 |
3.0 |
600 |
1 |
5.0 |
/ |
6.0 |
12.0 |
16.0 |
2 |
KR600-160 |
0.16 |
0.32 |
3.0 |
600 |
1 |
5.0 |
/ |
4.0 |
10.0 |
15.0 |
2 |
|
|
|
|
|
|
|
| Operating time/electric current relations chart(25℃) |
 |
|
| Operating current/working conditions temperature relations table |
Model |
Ambient Temperature( ℃ ) |
-40 |
-20 |
0 |
25 |
40 |
50 |
60 |
70 |
85 |
KR600-150 |
0.238 |
0.211 |
0.183 |
0.150 |
0.128 |
0.115 |
0.101 |
0.088 |
0.067 |
KR600-160 |
0.250 |
0.220 |
0.195 |
0.160 |
0.137 |
0.123 |
0.110 |
0.095 |
0.074 |
|
|
|
|
|
Product
model |
A |
B |
C |
D |
E |
Max |
Max |
Max |
Min |
Max |
KR600-150 |
13.5 |
12.6 |
6.0 |
4.7 |
5.0 |
KR600-160 |
13.5 |
12.6 |
6.0 |
4.7 |
5.0 |
|
|

 |
|
|
| |
Upward Next Altogether 10 pages |
|